Delta IED-S Series User Manual page 157

Integrated elevator drive
Table of Contents

Advertisement

Chapter 9 Digital Keypad | IED-S
4.
Fault Record
Press
ENTER
KPC-CE01 does not support
this function.
5.
Display Setup
Press ENTER to display the
Once the keypad is unlocked, turning the power off and then back on does
not lock the keypad.
Able to store 6 fault codes (Keypad V1.02 and previous versions)
Able to store 30 fault codes (Keypad V1.20 and later versions)
The most recent fault record shows as the first record. Choose a fault record
to see details such as date, time, frequency, current, voltage, and DC bus
voltage.
to select.
NOTE
The drive fault actions are recorded and saved to the KPC-CC01. When
you remove the KPC-CC01 and connect it to another drive, the previous
fault records are not deleted. The new fault records of the new drive
continue to be added to the KPC-CC01.
1. Contrast
If you do not press ESC, the keypad automatically
returns to this screen.
The keypad is still locked. When you press any key,
the screen shows the message on the left.
Press ESC for 3 seconds to unlock the keypad and
the keypad returns to this screen. All keys on the
keypad are functional.
Press Up or Down to select a fault record.
After selecting a fault code, press ENTER to see that
fault record's details.
Press Up or Down to see the fault record's details
such as date, time, frequency, current, voltage, and
DC bus voltage.
Press ESC to return to the Fault Record screen.
Press Up or Down to select the next fault record.
After selecting a fault record, press ENTER to see
that fault record's details.
Press Up or Down to see the fault record's details
such as date, time, frequency, current, voltage, and
DC bus voltage.
Press Up or Down to adjust the setting
value.
9-10