Chapter 12 Descriptions of Parameter Settings

00 System Monitoring

Present Fault Code
Settings 0–65535
Speed Command
Settings 0–65535
 Sets the speed command.
HVX1–HVX5 Status
Settings 0000h–FFFFh
 The high-voltage input terminal status for IED-S.
 LED display
X1–X16 Status
Settings 0000h–FFFFh
 The low-voltage input terminal status for IED-S.
5: Emergency stop, using Pr.04-29 (Inspection Deceleration)
6: Braking force test
7: EPS runs
8: Braking force test ended
10: Inspection stops, using Pr.04-29 (Inspection Deceleration)
15: Executes DC braking, stopping at zero speed control
20: Runs multi-step speed using Pr.04-11 (Re-leveling Deceleration)
deceleration to zero speed
25: Pr.04-00 (Speed at Emergency)
30: Pr.04-01 (Inspection Speed)
40: Pr.04-05 (Leveling Speed)
45: Pr.04-04 (Non-leveling Speed)
55: Pr.04-03 (Hoistway Auto-tuning Speed)
60: Pr.04-02 (Speed at Returning to Two Ends of the Hoistway)
65: Speed at direct docking
66: Direct docking enables zero speed
70: Does not output
75: Drive Pr.01-22 (JOG Frequency) setting value is being modified
76: Auto-tunes
77: No speed command
80: No speed command exceeds 0.1 second or STO is not ON
The display for digital keypad KPC-CC01
12-00-1
Chapter 12 Descriptions of Parameter Settings | IED-S
: You can set this parameter during operation.
Default: Read only
Default: Read only
Default: Read only
Default: Read only