Chapter 12 Descriptions of Parameter Settings | IED-S
 Serviced physical floor 1S–64S at the rear door
 See Pr.05-02 for details on the setting method.
 Setting method of LED display
Door Open Time during Hall Calls
Settings
 Sets the door opening time when the elevator arrives at the designated floor during hall calls.
Door Open Time during Car Calls
Settings
 Sets the door opening time for the door open button in the car.
 Sets the door opening time when the elevator arrives at the designated floor during car calls.
Door Open Extended Time
Settings
 Sets the door opening time for the door open extended button in the car.
Disability Door Open Time
Settings
 Sets the door opening time for the disability door open button in the car.
Door Open Time Protection
Settings
 0: The door opening time protection function is disabled.
 If IED-S does not receive any door open limit signal after the door opens and exceeds Pr.05-14
setting time, the fault code F225 or F227 occurs and the door closes.
Door Close Time Protection
Settings
 0: The door closing time protection function is disabled.
 If the elevator door does not close for Pr.05-15 setting time after the door closes, the fault code
F226 or F228 occurs and the door opens.
Number of Times for Door Close Protection
Settings
Setting method of digital keypad KPC-CC01
0.0–6553.5 sec.
0.0–6553.5 sec.
0.0–6553.5 sec.
0.0–6553.5 sec.
0–100 sec.
0–100 sec.
0–100
0: No limit on the number of times for door close protection
12-05-2
Default: 5.0
Default: 5.0
Default: 30.0
Default: 9.0
Default: 10
Default: 10
Default: 5