Chapter 14 Fault Codes | IED-S
Code#
KPC-CC01 Display
F228
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F229
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F230
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F231
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F232
Fault Name
Rear door close time
Fault occurs when the elevator door does not close after
exceeds
the rear door closes and exceeds Pr.05-15 setting time
Action and Reset
The rear door stops closing and opens
Pr.05-15 (Door Close Time Protection)
Resets automatically
Fault Name
Fault occurs when the number of times that F226 (front
Front door close times
door close time exceeds) occurs is larger than Pr.05-16
exceed
(Number of Times for Door Close Protection) in one
hour
Action and Reset
The front door stops closing and opens. The front door remains open and does
not close automatically. The front door close button flashes quickly.
Pr.05-15 (Door Close Time Protection), Pr.05-16 (Number of Times for Door
Close Protection)
Press the close button of the front door
Fault Name
Fault occurs when the number of times that F228 (rear
Rear door close times
door close time exceeds) occurs is larger than Pr.05-16
exceed
(Number of Times for Door Close Protection) in one
hour
Action and Reset
The rear door stops closing and opens. The rear door remains open and does
not close automatically. The rear door close button flashes quickly.
Pr.05-15 (Door Close Time Protection), Pr.05-16 (Number of Times for Door
Close Protection)
Press the close button of the rear door
Fault Name
GSL (Gate safety hatch
Fault occurs when GSL (Gate safety hatch low voltage)
low voltage) is OFF
signal is OFF in non-door zone
Action and Reset
Stops urgently
MI=19 GSL (Gate safety hatch low voltage)
Resets automatically once the fault is cleared
Fault Name
Fault occurs when either of the following conditions
happen:
GSL (Gate safety hatch
low voltage) contact
sticking
Action and Reset
14-24
Description
Description
Description
Description
Description
1. The door opens in the door zone, layer door signal
is OFF, but GSL (Gate safety hatch low voltage)
contact remains ON.
2. The door opens in the door zone, the door has
started to reach its open position, but GSL (Gate
safety hatch low voltage) contact remains ON.