Chapter 12 Descriptions of Parameter Settings | IED-S
ICB_1 Output
Settings
 The output status for the car command board at the front door (ICB_1).
 LED display
Current Floor
Settings
 Sets the current floor of the host controller. Make sure Pr.00-17 is the same as the current floor
for the drive (Pr.13-18). Otherwise, fault code F144 occurs.
Target Floor
Settings
 Set the floor that the elevator runs toward.
Furthest Floor
Settings
 Sets the floor that the elevator finally arrives in its current running direction.
Current Position (H)
Settings
 The elevator's current high position.
Current Position (L)
Settings
 The elevator's current low position.
Number of Times for Running (Ten Thousand Times)
Settings
 Accumulated number of times for the elevator's running (Unit: ten thousand).
Number of Times for Running (Times)
Settings
 Accumulated number of times for the elevator's running (Unit: times).
Accumulated Running Time (Hour)
Settings
 Accumulated running time for the elevator (Unit: hour).
0000h–FFFFh
The display for digital keypad KPC-CC01
0–65535S
0–65535S
0–65535S
-32768–32767 m
3276.8–3276.7 mm
0–65535
0–9999
0–65535
12-00-6
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: 0
Default: 0
Default: 0