System Control
Settings 0000h
 Setting method:
Bit0
Setting
0001h
Value
Setting method of LED display
 Bit 0=1: PDFF function is enabled, and a set of ASR setting is automatically generated.
 Bit 7=1: Zero speed position control is enabled (see the Elevator Timing Diagram in this Section).
This function is only valid for permanent magnet synchronous motor (PM).
 Bit 9=1: Static PG origin auto-tuning with load is enabled by PGHSD-x, and the mechanical brake
must be engaged.
Current Floor of the Drive
Settings 1–64
 Sets the current floor of the drive. Make sure Pr.13-18 is the same as the current floor for the host
controller (Pr.00-17). Otherwise, fault code F144 occurs.
Pulse Adjustment Condition
Settings 0–100
 Automatically adjusts the current pulse difference when elevator runs through leveling sensors.
 0–100 is the percentage of automatic adjustment in the current pulse difference.
Maximum Elevator Speed Percentage
Settings 30–100
 Sets the current elevator speed (current rated speed × Pr.13-20)
 After elevator tuning is finished, you can use this parameter to reduce elevator speed to avoid
runaway during test run.
 If you need to set the elevator running speed to be slower than "elevator's rated speed m/s", use
Pr.13-20 instead of Pr.13-03 (Elevator Rated Frequency), Pr.13-29 (Elevator Rated Speed), or
Pr.13-08 (Motor Rated Speed).
Motor Auto-tuning
Settings 0–3
 Set the elevator position near the middle floors before auto-tuning.
FFFFh
Bit 0=0: No function
Bit 0=1: ARS auto-tuning; PDFF enabled; speed bandwidth control enabled
Bit 7=0: No function
Bit 7=1: Zero speed position control is enabled
Bit 9=0: Dynamic PG origin auto-tuning with load (supported by PGHSD-x)
Bit 9=1: Static PG origin auto-tuning with load by enabling PGHSD-x
Bit7
Bit9
Bit0 & Bit7
0080h
0200h
0081h
Setting method of digital keypad KPC-CC01
0: No function
1: Only for an unloaded motor; auto-measures the magnetic pole offset angle
(PM)
2: Executes motor auto-ting (IM / PM)
3: Auto-measures the magnetic pole offset angle (PM)
12-13-3
Chapter 12 Descriptions of Parameter Settings | IED-S
Bit0 & Bit9
Bit7 & Bit9
0201h
0280h
Default: 0281h
Bit0 & Bit7 & Bit9
0281h
Default: 1
Default: 100
Default: 50
Default: 0