System Control
Settings 0000h
Setting method:
Bit0
Setting
0001h
Value
Setting method of LED display
Bit 0=1: PDFF function is enabled, and a set of ASR setting is automatically generated.
Bit 7=1: Zero speed position control is enabled (see the Elevator Timing Diagram in this Section).
This function is only valid for permanent magnet synchronous motor (PM).
Bit 9=1: Static PG origin auto-tuning with load is enabled by PGHSD-x, and the mechanical brake
must be engaged.
Current Floor of the Drive
Settings 1–64
Sets the current floor of the drive. Make sure Pr.13-18 is the same as the current floor for the host
controller (Pr.00-17). Otherwise, fault code F144 occurs.
Pulse Adjustment Condition
Settings 0–100
Automatically adjusts the current pulse difference when elevator runs through leveling sensors.
0–100 is the percentage of automatic adjustment in the current pulse difference.
Maximum Elevator Speed Percentage
Settings 30–100
Sets the current elevator speed (current rated speed × Pr.13-20)
After elevator tuning is finished, you can use this parameter to reduce elevator speed to avoid
runaway during test run.
If you need to set the elevator running speed to be slower than "elevator's rated speed m/s", use
Pr.13-20 instead of Pr.13-03 (Elevator Rated Frequency), Pr.13-29 (Elevator Rated Speed), or
Pr.13-08 (Motor Rated Speed).
Motor Auto-tuning
Settings 0–3
Set the elevator position near the middle floors before auto-tuning.
FFFFh
–
Bit 0=0: No function
Bit 0=1: ARS auto-tuning; PDFF enabled; speed bandwidth control enabled
Bit 7=0: No function
Bit 7=1: Zero speed position control is enabled
Bit 9=0: Dynamic PG origin auto-tuning with load (supported by PGHSD-x)
Bit 9=1: Static PG origin auto-tuning with load by enabling PGHSD-x
Bit7
Bit9
Bit0 & Bit7
0080h
0200h
0081h
Setting method of digital keypad KPC-CC01
0: No function
1: Only for an unloaded motor; auto-measures the magnetic pole offset angle
(PM)
2: Executes motor auto-ting (IM / PM)
3: Auto-measures the magnetic pole offset angle (PM)
12-13-3
Chapter 12 Descriptions of Parameter Settings | IED-S
Bit0 & Bit9
Bit7 & Bit9
0201h
0280h
Default: 0281h
Bit0 & Bit7 & Bit9
0281h
Default: 1
Default: 100
Default: 50
Default: 0