Delta IED-S Series User Manual page 400

Integrated elevator drive
Table of Contents

Advertisement

Code#
KPC-CC01 Display
F190
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F191
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F192
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F193
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F194
Action
Related Parameters
Reset Method
Fault Name
Fault occurs when target floor is higher than current
Downward target error
floor after giving a downward command as elevator runs
in direct docking
direct docking
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
Fault Name
Fault occurs when desired running direction is opposite
INV DRV DIR error
to direction fed back by the drive
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
Fault Name
Fault occurs when desired running direction is opposite
INV VFD DIR error
to direction gives to the drive
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
Fault Name
Fault occurs when direction gives to the drive is
VFD DRV DIR error
opposite to direction fed back by the drive
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
Fault Name
Fault occurs when speed is larger than Pr.03-37 (ULS1
ULS1 over-speed
Over-speed Protection) after ULS1 (First one upward
forced deceleration) activates during upward running
Action and Reset
Stops urgently
MI=35 ULS1 (First one upward forced deceleration)
Pr.03-37 (ULS1 Over-speed Protection)
Resets automatically after 60 seconds
14-19
Chapter 14 Fault Codes | IED-S
Description
Description
Description
Description
Description

Advertisement

Table of Contents
loading

Table of Contents