Delta IED-S Series User Manual page 317

Integrated elevator drive
Table of Contents

Advertisement

Chapter 12 Descriptions of Parameter Settings | IED-S
Setting
Value
127
SCON (Voice control)
128
SFIR (Voice fire alarm)
129
SER (Voice earthquake)
130
SFLOOD (Voice flood)
131
SUPS (Voice power loss)
132
SERR (Voice elevator failure)
133
SPACE (Voice blank)
DCBL1 (Front door close button
150
lamp)
DOBL1 (Front door open button
151
lamp)
DOBHL1 (Front door open
152
extended button lamp)
153
FULL (Full-load)
154
OLD (Overload)
CLBZ (Door closing pre-warning
155
buzzer)
DCBL2 (Rear door close button
167
lamp)
DOBL2 (Rear door open button
168
lamp)
DOBHL2 (Rear door open
169
extended button lamp)
DCBL1B (Front door close
170
auxiliary button lamp)
DOBL1B (Front door open
171
auxiliary button lamp)
DOBHL1B (Front door open
172
auxiliary extended button lamp)
DCBL2B (Rear door close
173
auxiliary button lamp)
DOBL2B (Rear door open
174
auxiliary button lamp)
DOBHL2B (Rear door open
175
auxiliary extended button lamp)
X_INV1
X_INV2
X_INV3
Y_INV
HVX_INV
Settings 0000h–FFFFh
 This function sets the contact from N.O. to N.C. or vice versa (reverse contact). Use this function
for test only. Do NOT use it under normal mode for elevator.
 If you have set Pr.06-01 to thousands digit, namely reverse contact, setting it at Pr.06-39 makes
the reverse function invalid.
 Pr.06-39 reverse contact setting: 1–16 = Pr.06-01–Pr.06-16
MO Function
12-06-10
Description
use
Voice shutdown and is in control operation
Voice is in fire alarm
Voice is under earthquake
Voice is at flood
Voice is lack of power
Voice elevator is in failure
Voice blank
Outputs the signal of front door close button lamp
Outputs the signal of front door open button lamp
Outputs the signal of front door open extended button
lamp
Outputs full-load signal
Outputs overload signal
Door closing pre-warning buzzer
Outputs the signal of rear door close button lamp
Outputs the signal of rear door open button lamp
Outputs the signal of rear door open extended button
lamp
Outputs the signal of front door close auxiliary button
lamp
Outputs the signal of front door open auxiliary button
lamp
Outputs the signal of front door open auxiliary extended
button lamp
Outputs the signal of rear door close auxiliary button
lamp
Outputs the signal of rear door open auxiliary button
lamp
Outputs the signal of rear door open auxiliary extended
button lamp
Default: 0000h
Default: 0000h
Default: 0000h
Default: 0000h
Default: 0000h

Advertisement

Table of Contents
loading

Table of Contents