count. When time exceeds Pr.03-75, each elevator automatically runs to the nearest main
group control to standby.
3. If the number of main group controls is smaller than the number of elevators, elevators that
have no main group control for standby will automatically run to Pr.03-68 (First Main Group
Control). If you do not set Pr.03-68, these elevators stay at where they were for standby.
4. Pr.03-68 (First Main Group Control) is also the main upward peak; Pr.03-74 (Seventh Main
Group Control) is also the main downward peak.
5. If there is any car/hall call occurs while elevators run to main group control for standby,
dispersed waiting will be cancelled, and elevators stop at the nearest floor.
Upward Peak 1 Begin
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the beginning time for the first upward peak hours. See Pr.03-90 peak running in group
control operation for details.
Upward Peak 1 End
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the end time for the first upward peak hours. See Pr.03-90 peak running in group control
operation for details.
Downward Peak 1 Begin
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the beginning time for the first downward peak hours. See Pr.03-90 peak running in group
control operation for details.
Downward Peak 1 End
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the end time for the first downward peak hours. See Pr.03-90 peak running in group control
operation for details.
Upward Peak 2 Begin
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the beginning time for the second upward peak hours. See Pr.03-90 peak running in group
control operation for details.
Upward Peak 2 End
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Sets the end time for the second upward peak hours. See Pr.03-90 peak running in group control
operation for details.
Downward Peak 2 Begin
Settings
0–2359
0–2359
0–2359
0–2359
0–2359
0–2359
0–2359
12-03-15
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0