Chapter 14 Fault Codes | IED-S
Code#
KPC-CC01 Display
F204
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F205
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F221
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F222
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F223
Fault Name
Fault occurs when target floor is larger than lowest floor
Target error 3
during downward direct docking running
Action and Reset
Stops urgently
Pr.00-18 (Target Floor), Pr.03-02 (Lowest Physical Floor)
Resets automatically after 60 seconds
Fault Name
Fault occurs when target floor is larger than nearest
Target error 4
stop floor during downward direct docking running
Action and Reset
Stops urgently
Pr.00-18 (Target Floor), Pr.00-35 (Nearest Stop Floor)
Resets automatically after 60 seconds
Fault Name
GSH (Gate safety
Fault occurs when GSH (Gate safety hatch high
hatch high voltage) is
voltage) signal is OFF in non-door zone
OFF
Action and Reset
Stops urgently
MI=18 GSH (Gate safety hatch high voltage)
Resets automatically once the fault is cleared
Fault Name
Fault occurs when either of the following conditions
happen:
GSH (Gate safety
hatch high voltage)
contact sticking
Action and Reset
Stops urgently
MI=18 GSH (Gate safety hatch high voltage),
MI=21 DSH (Layer door safety hatch high voltage),
MI=22 DSL (Layer door safety hatch low voltage),
MI=100 OLT1 (Front door reaches its open position),
MI=101 OLT2 (Rear door reaches it open position)
Switch to the manual mode, press the RESET key on the digital keypad, press
the external reset device, or power-on again (choose either)
Fault Name
DSH (Layer door
Fault occurs when DSH (Layer door safety hatch high
safety hatch high
voltage) signal is OFF in non-door zone
voltage) is OFF
14-22
Description
Description
Description
Description
1. The door opens in the door zone, layer door signal
is OFF, but GSH (Gate safety hatch high voltage)
contact remains ON.
2. The door opens in the door zone, the door has
started to reach its open position, but GSH (Gate
safety hatch high voltage) contact remains ON.
Description