Delta IED-S Series User Manual page 404

Integrated elevator drive
Table of Contents

Advertisement

Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F224
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F225
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F226
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F227
Action
Related Parameters
Reset Method
Action and Reset
Stops urgently
MI=21 DSH (Layer door safety hatch high voltage)
Resets automatically once the fault is cleared
Fault Name
Fault occurs when either of the following conditions
happen:
DSH (Layer door
safety hatch high
voltage) contact
sticking
Action and Reset
Stops urgently
MI=18 GSH (Gate safety hatch high voltage),
MI=19 GSL (Gate safety hatch low voltage),
MI=21 DSH (Layer door safety hatch high voltage),
MI=100 OLT1 (Front door reaches its open position),
MI=101 OLT2 (Rear door reaches it open position)
Switch to the manual mode, press the RESET key on the digital keypad, press
the external reset device, or power-on again (choose either)
Fault Name
Fault occurs when IED-S does not receive any front
Front door open time
door open limit signal after the front door opens and
exceeds
exceeds Pr.05-14 setting time
Action and Reset
The front door stops opening and closes
Pr.05-14 (Door Open Time Protection)
Resets automatically
Fault Name
Front door close time
Fault occurs when the elevator door does not close after
exceeds
the front door closes and exceeds Pr.05-15 setting time
Action and Reset
The front door stops closing and opens
Pr.05-15 (Door Close Time Protection)
Resets automatically
Fault Name
Fault occurs when IED-S does not receive any rear door
Rear door open time
open limit signal after the rear door opens and exceeds
exceeds
Pr.05-14 setting time
Action and Reset
The rear door stops opening and closes
Pr.05-14 (Door Open Time Protection)
Resets automatically
14-23
Description
1. The door opens in the door zone, gate signal is
OFF, but DSH (Layer door safety hatch high
voltage) contact remains ON.
2. The door opens in the door zone, the door has
started to reach its open position, but DSH (Layer
door safety hatch high voltage) contact remains ON.
Description
Description
Description
Chapter 14 Fault Codes | IED-S