Delta IED-S Series User Manual page 222

Integrated elevator drive
Table of Contents

Advertisement

Pr.
Parameter Name
Door Open/Close Mode when
05-24
in Manual Operation
Door Open Delayed Time at
05-25
Stop
Closing Time for Door Open
05-26
Signal
Closing Time for Door Close
05-27
Signal
Time for No Response to Hall
05-28
Calls
Chapter 11 Summary of Parameter Settings | IED-S
Setting Range
1: Door opens automatically when the elevator arrives
at the designated floor
0–2
0: Door open/close signal does not output
1: The door does not open, and automatically closes if
the door is not closing.
2: The door opens automatically when the elevator
stops in the leveling area; the door closes when you
press the upward or downward operation button for the
manual mode respectively.
0.0–2.0 sec.
0.0–600.0 sec.
0.0: The door opening signal outputs continuously
0.1–600.0: Starts to count the time after the door opens
to its full position. The door opening signal stops output
when the counting time exceeds Pr.05-26.
0.0–600.0 sec.
0.0: The door closing signal outputs continuously
0.1–600.0: Starts to count the time after the door
closes. The door closing signal stops output when the
counting time exceeds Pr.05-27.
0–60 sec.
11-21
Default
0
0.5
0.0
0.0
0