Chapter 12 Descriptions of Parameter Settings

09 Floor Position 1

 Parameter Group 09 sets the hoistway parameter values. You can use hoistway auto-tuning to
obtain the hoistway parameter values.
 Each floor uses two sets of parameters; one is the high position (meter/m), and the other is the
low position (millimeter/mm) to indicate the accurate floor position. For example, the second floor
uses Pr.09-10 and Pr.09-11 to indicate floor position. If Pr.09-10 is set to 7, and Pr.09-11 is set to
1234, then the second floor position is 7.1234 meter (m).
Current Position (H)
Settings -32768–32767 m
Current Position (L)
Settings -3276.8–3276.7 mm
Current Pulse 10k (H)
Settings 0–65535 10k
Current Pulse (L)
Settings 0–65535
Leveling Plate Length (H)
Settings 0–65535 m
Leveling Plate Length (L)
Settings 0.0–6553.5 mm
Leveling Clearance (H)
Settings 0–65535 m
Leveling Clearance (L)
Settings 0.0–6553.5 mm
1S High Position
Settings 0–65535 m
1S Low Position
Settings 0.0–6553.5 mm
Chapter 12 Descriptions of Parameter Settings | IED-S
: You can set this parameter during operation.
12-09-1
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only
Default: Read only