Chapter 12 Descriptions of Parameter Settings | IED-S
 LED display
X17–X25 Status
Settings 0000h–FFFFh
The low-voltage input terminal status for IED-S.
 LED display
Y1–Y8 Status
Settings 0000h–FFFFh
 The low-voltage output terminal status for IED-S.
 LED display
Elevator Speed Detection
Settings 0.000–65.535
 Sets the running speed for the elevator (Unit: m/s).
Elevator Mode 0
Settings
The display for digital keypad KPC-CC01
The display for digital keypad KPC-CC01
The display for digital keypad KPC-CC01
0000h–FFFFh
bit 0: Manual (EIS Emergency Operation)
bit 1: Manual (INSCP inspection)
bit 2: Manual (MATPT inspection)
bit 3: Manual (TCI inspection)
bit 4: Manual (INSIC inspection)
bit 5: Manual (DBP Doorlock bypass)
bit 6: Auto-resets at flood
bit 7: Does not auto-rest at flood
bit 8: When using emergency power supply (UPS), the elevator runs to
designated floor and stops.
bit 9: UPS safety landing
bit 10: EPS safety landing
bit 11: Car returns to the main landing at fire emergency
12-00-2
Default: Read only
Default: Read only
Default: Read only