Delta IED-S Series User Manual page 22

Integrated elevator drive
Table of Contents

Advertisement

2-2 Airflow and Power Dissipation
Model No.
External Internal
IED022S21A
48.5
IED037S21A
48.5
IED055S23A
48.5
IED075S23A
48.5
IED110S23A
47.9
IED150S23A
64.6
IED185S23A
102.3
IED220S23A
102.8
IED055S43A
48.5
IED075S43A
48.5
IED110S43A
47.9
IED150S43A
46.1
IED185S43A
46.1
IED220S43A
102.8
IED300S43A
83.7
IED370S43A
179
IED450S43A
179
IED550S43A
179
IED750S43A
186
Airflow Rate for Cooling
Flow Rate [cfm]
Total
External Internal
-
48.5
-
48.5
-
48.5
-
48.5
-
47.9
-
64.6
-
102.3
-
102.8
-
48.5
-
48.5
-
47.9
-
46.1
-
46.1
-
102.8
-
83.7
30
209
30
209
30
209
30
216
Flow Rate [m
3
/hr]
Total
82.4
-
82.4
82.4
-
82.4
82.4
-
82.4
82.4
-
82.4
81.4
-
81.4
109.8
-
109.8
173.8
-
173.8
174.7
-
174.7
82.4
-
82.4
82.4
-
82.4
81.4
-
81.4
78.4
-
78.4
78.4
-
78.4
174.7
-
174.7
142.2
-
142.2
304
51
355
304
51
355
304
51
355
316
51
367
2-3
Chapter 2 Installation | IED-S
Power Dissipation for
AC Motor Drive
Power Dissipation [W]
Loss External
Internal
(Heat Sink)
60
36
84
46
212
67
292
86
355
121
490
161
638
184
723
217
185
55
249
71
337
94
302
123
391
139
642
141
839
180
803
252
1014
270
1244
275
1541
338
Total
96
130
279
379
476
651
822
939
240
320
431
425
529
783
1019
1055
1284
1519
1878

Advertisement

Table of Contents
loading

Table of Contents