Chapter 13 Warning Codes | IED-S
Code#
KPC-CC01 Display
1112
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
1113
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
1114
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
1115
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
1116
Action
Related Parameters
Reset Method
Warning Name
Braking force, Test,
Warning occurs when the braking force test is finished
Qualified
and the test is qualified
Action and Reset
N/A
Pr.03-60–Pr.03-67 (parameters relate to braking force test)
Resets automatically after five seconds
Warning Name
Fault, Unqualified,
Warning occurs when Pr.03-67 (Brake Test Starting) is
Braking force
set to 1, and the elevator is currently malfunctioned
Action and Reset
Pr.03-67 (Brake Test Starting) is set to 0, and the fault code F150 (Unqualified
braking force test) occurs after five seconds.
Pr.03-67 (Brake Test Starting)
Resets automatically after five seconds
Warning Name
Warning occurs when Pr.03-67 (Brake Test Starting) is
Button, Unqualified,
set to 1, and you press the upward or downward
Braking force
operation button for the manual mode.
Action and Reset
Pr.03-67 (Brake Test Starting) is set to 0, and the fault code F150 (Unqualified
braking force test) occurs after five seconds.
Pr.03-67 (Brake Test Starting)
Resets automatically after five seconds
Warning Name
Warning occurs when running the manual braking force
test, and the door does not close after you set Pr.03-67
(Brake Test Starting) to 1.
Wait, Braking force test
Warning occurs when running the automatic braking
force test once per day in specified time, and the
elevator is in use by passengers.
Action and Reset
The door automatically closes when running the manual braking force test.
The door does not close automatically when running the automatic braking force
test once per day.
Pr.03-67 (Brake Test Starting)
Resets automatically
Warning Name
Warning occurs when running the automatic braking
Recall, Braking force
force test once per day, and the elevator automatically
test
runs to the designated floor.
Action and Reset
The car call of the floor specified by Pr.03-66 (Brake Test Floor) is automatically
registered.
Pr.03-66 (Brake Test Floor)
Resets automatically