03 Function Settings
Pr.
Parameter Name
03-00
Hoistway Auto-tuning
03-01
Highest Physical Floor
03-02
Lowest Physical Floor
03-03
Group Control Station Number
03-04
Group Control Enabled
Main Landing for Standby While
03-05
Idling
Idle Time Before Returning to the
03-06
Main Landing for Standby
03-07
Car Lighting Disabled While Idling
03-08
Car Fan Disabled While Idling
03-09
UPS Designated Floor
Light Sensor and Safety Edges
03-10
Alarm
03-11
Service Floor 16–1
03-12
Service Floor 32–17
03-13
Service Floor 48–33
03-14
Service Floor 49–64
Automatic Safety Landing for
03-15
Severe Earthquake
03-16
Position Difference Protection
03-17
Auto-leveling After Re-power
03-18
Delayed Time for Leveling Switch
Seismic S-wave Deceleration
03-19
Time
03-20
Door Pre-open at Stop
03-21
Re-leveling After Door Open
03-22
Reverse Pulse Logic
03-23
Number of Fault Reset
03-24
Constant Running Protection Time
Chapter 11 Summary of Parameter Settings | IED-S
Setting Range
0–1
1–64F
1–64F
0–7
0–1
0: Single control operation
1: Group control operation
1–64S
0–65535 sec.
0–65535 sec.
0–65535 sec.
0–164
0–199 sec.
0–65535
0–65535
0–65535
0–65535
0–1
0: Disabled
1: When "severe earthquake" occurs, the automatic
safety landing activates
0.0–1000.0 mm
0–3
0: Disabled
1: Runs to the bottom floor for leveling after
power-on again
2: Runs to the top floor for leveling after power-on
again
3: Automatically runs downward or upward for
leveling, depending on the elevator's current floor
0.000–2.000 sec.
0.0–6553.5 sec.
0–90 mm
0: Door opens until the elevator reaches the leveling
1–90: Door opens before the elevator is near the
leveling
0–1
0: Re-leveling is not allowed after the door opens
1: Re-leveling is allowed after the door opens
0–1
0: The same as the setting direction
1: Opposite to the setting direction
0–10 times
0: Reset function is disabled
1–10: The fault automatically resets if the number of
the same fault occurred does not exceed the
Pr.03-23 setting in one hour
1–600 sec.
11-15
Default
0
1
1
0
0
1
0
600
30
0
0
65535
65535
65535
65535
1
300.0
0
0.200
7.0
0
0
0
1
120