Delta IED-S Series User Manual page 406

Integrated elevator drive
Table of Contents

Advertisement

Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F233
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F234
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F235
Action
Related Parameters
Reset Method
Stops urgently
MI=19 GSL (Gate safety hatch low voltage),
MI=21 DSH (Layer door safety hatch high voltage),
MI=22 DSL (Layer door safety hatch low voltage)
MI=100 OLT1 (Front door reaches its open position),
MI=101 OLT2 (Rear door reaches it open position)
Switch to the manual mode, press the RESET key on the digital keypad, press
the external reset device, or power-on again (choose either)
Fault Name
DSL (Layer door safety
Fault occurs when DSL (Layer door safety hatch low
hatch low voltage) is
voltage) signal is OFF in non-door zone
OFF
Action and Reset
Stops urgently
MI=22 DSL (Layer door safety hatch low voltage)
Resets automatically once the fault is cleared
Fault Name
Fault occurs when either of the following conditions
happen:
DSL (Layer door safety
hatch low voltage)
contact sticking
Action and Reset
Stops urgently
MI=18 GSH (Gate safety hatch high voltage),
MI=19 GSL (Gate safety hatch low voltage),
MI=22 DSL (Layer door safety hatch low voltage),
MI=100 OLT1 (Front door reaches its open position),
MI=101 OLT2 (Rear door reaches it open position)
Switch to the manual mode, press the RESET key on the digital keypad, press
the external reset device, or power-on again (choose either)
Fault Name
Discharge resistance
Fault occurs when IBRTS (Drive's discharge resistance
temperature is too high
temperature switch) detects temperature is too high
Action and Reset
The elevator stops at the nearest floor within 20 seconds. Otherwise, the
elevator stops urgently. After stopping, BU (brake unit contactor) is OFF, and the
elevator stops running.
MI=58 IBRTS (Drive's discharge resistance temperature switch)
MO=7 BU (Contactor of brake unit)
Press the RESET key on the digital keypad, press the external reset device, or
power-on again (choose either)
14-25
Description
Description
1. The door opens in the door zone, gate signal is
OFF, but DSL (Layer door safety hatch low voltage)
contact remains ON.
2. The door opens in the door zone, the door has
started to reach its open position, but DSL (Layer
door safety hatch low voltage) contact remains ON.
Description
Chapter 14 Fault Codes | IED-S