10-6-5 Confirmation of Sensor Signal
Set the elevator position near the middle floor first, and then use the upward and downward
operations for the inspection mode to check the sensor signals:
1. Check if the signals and installation positions of DZU, SX1, and DZD for each floor are
correct
2. Check if the signals and installation positions of upward and downward forced deceleration
sensors are correct
3. Check if the signals and installation positions of the upper limit and lower limit are correct
10-6-6 Pr.02-06 Door Function Test
 Valid only when in inspection mode.
 Setting value:
0: Normal mode
1: Front door is forced to open
2: Rear door is forced to open
3: Front and rear door are forced to open
4: Front and rear door are forced to close
 When
not in manual mode, Pr.02-06 is automatically set to 0, and the door is forced to open
 
both in leveling or non-leveling area.
10-6-7 Pr.03-51 ICB (Car Command Board) Function Setting