Clock-Minute
Settings
Clock-Second
Settings
No Display of Faults and Warnings
Settings
 All the setting values only set the display of faults and warnings, and do not affect the functions of
faults and warnings.
 When ten minutes have passed after you have set the value or when power-on again, Pr.02-31
automatically returns to 0.
 If you press the HAND key on the digital keypad KPC-CC01 more than five times in five seconds,
Pr.02-31 automatically sets to 1.
0–59
0–59
0–3
0: Digital keypad KPC-CC01 and LED panel display faults and warnings
1: Digital keypad KPC-CC01 does not display faults and warnings
2: LED panel does not display faults and warnings
3: Digital keypad KPC-CC01 and LED panel does not display faults and
warnings
12-02-7
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 0
Default: 0
Default: 0