4.
The usage of TCIN (traveling cable insertion), INSCP (control panel inspection switch), EIS
(emergency operation), TCI (cartop inspection switch), and INSIC (car inspection switch):
(1) Definition of Term:
a. Control panel in manual operation: signals, such as INSCP (control panel inspection
switch) and EIS (emergency operation), connected with the inspection signals in the
control panel.
b. Car in manual operation: signals, such as TCI (cartop inspection switch) and INSIC (car
inspection switch), connected with the inspection signals in the cartop board or car
command board.
c. CAR Link: the communication status between IED-S and cartop board.
(2) When to use:
With TCIN
function
Without TCIN
function
5.
Speed for different modes: In manual operation mode, the elevator runs with Pr.04-05 (Leveling
Speed) within Pr.04-18 (Low-speed Running Time When Enabled Manually) setting time. In
inspection mode, the elevator runs with Pr.04-01 (Inspection Speed). In emergency operation
mode, the elevator runs with Pr.04-04 (Non-leveling Speed). If the first one upward or downward
forced deceleration activates in the manual operation mode, the elevator runs with Pr.04-04
(Non-leveling Speed) instead. If the upper leveling, or lower leveling, or door zone switch
activates in the manual operation mode, the elevator runs with Pr.04-05 (Leveling Speed)
instead.
6.
Reset procedures of inspection from pit:
When in the mode of inspection from pit, the elevator does not change to automatic mode simply
because you switch the mode from pit inspection to automatic, unless you complete the steps
below:
(1) Change the pit inspection switch to automatic on the precondition that the safety hatch is
OFF, layer door safety hatch is OFF, and external reset device is not pressed.
(2) Switch the safety hatch to normal.
(3) Close the layer door.
(4) Press the external reset device to complete the reset. Or you can press the hall call button at
the bottom floor for three to six seconds and release it after layer door closes (step (3)) for
30 seconds. Pressing and holding it too long or too short does not work. Then, the elevator
changes to automatic mode successfully.
(5) If you set them incorrectly, you only have to repeat steps (1) to (4) after switching the pit
inspection switch to inspection.
TCIN
CAR LINK
ON
Normal
ON
Abnormal
OFF
Normal
OFF
Abnormal
X
Normal
X
Abnormal
10-23
Chapter 10 Auto-tuning Process | IED-S
Control panel in
Car in manual
manual
operation
operation
Not in manual
operation