Pr.
Parameter Name
00-62
Elevator Running Direction
Hoistway Auto-tuning Action
00-63
Status
Chapter 11 Summary of Parameter Settings | IED-S
Setting Range
bit 15: Station number 7 is main group control or not
0000h–FFFFh
bit 0: Host controller (controller) runs upward
bit 1: Host controller (controller) runs downward
bit 2: Host controller (controller) makes drive run
upward
bit 3: Host controller (controller) makes drive run
downward
bit 4: Drive responds receiving upward commands
bit 5: Drive responds receiving downward commands
bit 6: Upward high-speed enabled command
bit 7: Downward high-speed enabled command
bit 8: Runs upward after stop
bit 9: Runs downward after stop
bit 10: Hall call displays an upward arrow
bit 11: Hall call displays a downward arrow
bit 12: Car call displays a upward arrow
bit 13: Car call displays a downward arrow
0–65535
0: Not in INSCP (control panel inspection switch) or
EIS (electrical operation) mode
0: Not in INSCP (control panel inspection switch) or
EIS (electrical operation) mode
2: Still in inspection mode after setting Pr.03-00
(Hoistway Auto-tuning) = 1
3: Switch inspection switch to auto
10: Door does not close
11: Elevator starts to run downward
12: Elevator runs downward, first one downward
forced deceleration (DLS1) is ON
13: Elevator runs downward, first one downward
forced deceleration (DLS1) is ON
14: Elevator runs downward, first one downward
forced deceleration (DLS1) and leveling sensor are
ON
15: Lower leveling sensor (DZD) is ON, door zone
signal (SX1) and upper leveling sensor (DZU) are
OFF
16: Lower leveling sensor (DZD) and door zone
signal (SX1) are ON, upper leveling sensor (DZU) is
OFF
17: Lower leveling sensor (DZD), door zone signal
(SX1), and upper leveling sensor (DZU) are all ON
18: Lower leveling sensor (DZD) is OFF, door zone
signal (SX1) and upper leveling sensor (DZU) are
ON
19: Lower leveling sensor (DZD) and door zone
signal (SX1) are OFF, upper leveling sensor (DZU) is
ON
20: Lower leveling sensor (DZD), door zone signal
(SX1), and upper leveling sensor (DZU) are all OFF
21: Lower limit switch (LSD) is ON
24: Lower limit switch (LSD) is ON
25: Lower limit switch (LSD) is ON for more than 2
seconds
26: Elevator starts to run upward
27: Elevator runs upwards, first one upward forced
deceleration (ULS1) is ON
28: Elevator runs upwards, first one upward forced
deceleration (ULS1) is ON
29: Elevator runs upward, first one upward forced
deceleration (ULS1) and leveling sensor are ON
30: Elevator runs upward, first one upward forced
11-5