Code#
KPC-CC01 Display
F152
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F153
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F154
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F155
Action
Related Parameters
Reset Method
Fault Name
Detection is valid only when not in the manual mode or
not in door unlock board test mode. There are two
detection conditions:
Runs with door open
Action and Reset
Stops urgently
Pr.03-59 (Door Unlock Board Test)
Press the external reset device, press the RESET key on the digital keypad,
power-on again, or switch to the inspection mode to press both the upward and
downward operation buttons simultaneously for more than five seconds (choose
either)
Fault Name
Safety hatch low
Fault occurs when there is an error in the safety hatch
voltage error
signal for the elevator system (low voltage)
Action and Reset
Stops urgently
MI=16 SFL (Safety hatch low voltage)
Resets automatically once the signal is normal
Fault Name
Runs in an opposite
Fault occurs when the elevator running direction is
direction
opposite to the encoder direction.
Action and Reset
Three seconds
Pr.03-22 (Reverse Pulse Logic) or Pr.13-02 (Drive Output Direction)
When the elevator is in stop status, press the RESET key on the digital keypad,
press the external reset device, or power-on again (choose either)
Fault Name
Fault occurs when BK3 (Brake-3 travel switch) signal is
BK3 is not active
not active after brake contactor activates (ON)
Action and Reset
Stops urgently
MI=32 BK3 (Brake-3 travel switch)
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
14-11
Description
1. Fault occurs when both the gate safety hatch and
layer door safety hatch signals are OFF, and the
door zone signal changes from ON to OFF.
2. Both the gate safety hatch and layer door safety
hatch signals use their own relays to connect
multi-function terminals (MI=20 GSNC (N.C contact
of gate safety hatch contactor)) and MI=23 DSNC
(N.C. contact of layer door safety hatch contactor)).
Fault occurs when their signals are both OFF and
they are not in the manual mode for more than 30
seconds and not in the door zone.
Description