Settings
 Uses 16-bit setting for every sixteen floor. If the bit setting that corresponds to the floor is 1, the
elevator responds to the floor's call. If the bit setting that corresponds to the floor is 0, the elevator
does not respond to the floor's call.
 For example, in a building with elevator of ten floors, if you need to set the third and fifth floors as
non-service floors, which corresponds to bit 2 and bit 4 respectively, set Pr.03-11 to 65515
(0xFFEB) [=65535-2
 Setting method of LED display
Automatic Safety Landing for Severe Earthquake
Settings
Position Difference Protection
Settings
 When Pr.03-16=0, the position difference protection is disabled.
 If position difference exceeds Pr.03-16 setting while forced deceleration switch is activated, the
elevator stops urgently and the following fault codes occur: F173 (Upward forced deceleration 1),
F174 (Upward forced deceleration 2), F175 (Upward forced deceleration 3); F177 (Downward
forced deceleration 1), F178 (Downward forced deceleration 2), F179 (Downward forced
deceleration 3).
Auto-leveling After Re-power
Settings
Delayed Time for Leveling Switch
Settings
 Adjusts the leveling accuracy while re-leveling. If the elevator stops before reaching the accurate
leveling position, increase the delayed time. If the elevator stops after reaching the accurate
leveling position, decrease the delayed time.
Seismic S-wave Deceleration Time
Settings
When "seismic s-wave" occurs, the elevator stops at the nearest floor. If the elevator does not
decelerate within this setting time, the elevator is forced to emergency stop.
0–65535
-2
2
4
]. Use the same setting method for similar parameters.
Setting method of digital keypad KPC-CC01
0–1
0: Disabled
1: When "severe earthquake" occurs, the automatic safety landing activates
0.0–1000.0 mm
0–3
0: Disabled
1: Runs to the bottom floor for leveling after power-on again
2: Runs to the top floor for leveling after power-on again
3: Automatically runs downward or upward for leveling, depending on the
elevator's current floor
0.000–2.000 sec.
0.0–6553.5 sec.
12-03-3
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 65535
Default: 1
Default: 300.0
Default: 0
Default: 0.200
Default: 7.0