Chapter 12 Descriptions of Parameter Settings

04 Speed Curve

Speed at Emergency
Settings 0.00–0.30 m/s
 Sets the speed when the elevator runs with emergency power.
Inspection Speed
Settings 0.00–0.63 m/s
 Sets the inspection speed when the elevator executes the inspection.
Speed at Returning to Two Ends of the Hoistway
Settings 0.00–1.50 m/s
 Sets the speed during the elevator's position adjustment when returning to two ends of the
hoistway.
Hoistway Auto-tuning Speed
Settings 0.00–0.50 m/s
 Sets the speed during the elevator's hoistway auto-tuning.
Non-leveling Speed
Settings 0.01–0.30 m/s
 Sets the speed when the elevator stops at the non-leveling area to safely land at the nearest
floor.
Leveling Speed
Settings 0.01–0.15 m/s
 Sets the speed for elevator re-leveling.
Constant Speed Duration
Settings 0–3000
Acceleration
Settings 0.10–1.50 m/s
 Sets the acceleration for direct docking.
Deceleration
Settings 0.10–1.50 m/s
 Sets the deceleration for direct docking.
Chapter 12 Descriptions of Parameter Settings | IED-S
: You can set this parameter during operation.
2
2
12-04-1
Default: 0.15
Default: 0.25
Default: 0.50
Default: 0.20
Default: 0.12
Default: 0.04
Default: 500
Default: 0.40
Default: 1.50