Setting
MO Function
Value
12
ERR (Error output)
FIRLD (Main landing at fire
13
emergency)
14
RG (Rope gripper)
15
SY (Door unlock contactor)
QKOK (Earthquake control
16
finished)
17
SDBZ (Supervisory panel alarm)
18
ERHL (Severe earthquake light)
100
OP1 (Front door opens)
101
OP2 (Rear door opens)
102
CL1 (Front door closes)
103
CL2 (Rear door closes)
104
BZ (Buzzer)
BPSL (Doorlock bypass lighting
105
alarm)
106
UDCL (Car bottom light)
107
F (Car fan)
108
CLI (Car lighting)
109
LPT (Floor arrival clock)
110
LPTU (Upward floor arrival clock)
LPTD (Downward floor arrival
111
clock)
FCL1 (Front door forced close at
112
low speed)
FCL2 (Rear door forced close at
113
low speed)
S2XX0 (Voice announces the
114
floor arrives)
S2XX1 (Voice announces the
115
floor arrives)
S2XX2 (Voice announces the
116
floor arrives)
S2XX3 (Voice announces the
117
floor arrives)
S2XX4 (Voice announces the
118
floor arrives)
S2XX5 (Voice announces the
119
floor arrives)
120
SPK (Voice announcement)
121
SOP (Voice door open)
122
SCL (Voice door close)
123
SUP (Voice upward)
124
SDN (Voice downward)
125
SOLD (Voice overload)
126
SSEV (Voice EMT medical use )
Chapter 12 Descriptions of Parameter Settings | IED-S
Outputs when error occurs in elevator
Outputs when elevator arrives main landing at fire
emergency under fire mode.
Makes standby break (rope gripper) NOT brake when
LED indicator is ON.
Outputs only when re-leveling after door open and door
pre-opens at stop. Otherwise, SY is OFF.
Outputs after earthquake control operation procedure is
finished.
When "severe earthquake (ERH)" signal activates,
supervisory panel alarm bees until "severe earthquake
safety landing (ERGO)" switch is triggered.
ERHL light is ON when "severe earthquake (ERH)"
signal activates; ERHL light is OFF when "severe
earthquake (ERH)" signal resets.
Outputs front door open signal
Outputs rear door open signal
Outputs front door close signal
Outputs rear door close signal
Outputs when overload occurs or doorlock bypass is
activated.
Outputs when doorlock bypass is activated. The alarm is
ON for 0.4 seconds and OFF for 0.4 seconds.
Steady ON when in inspection. The light is ON for 0.4
seconds and OFF for 0.4 seconds when doorlock bypass
is activated.
Outputs fan signal. Fan stops when LED indicator is ON.
Outputs lighting signal. Lighting is off when LED indicator
is ON.
Outputs floor arrival clock signal for 0.5 second
Outputs floor arrival clock signal when arriving at
designated floor upward for 0.5 second.
Outputs floor arrival clock signal when arriving at
designated floor downward for 0.5 second.
Executes front door forced close at low speed when LED
indicator is ON.
Executes rear door forced close at low speed when LED
indicator is ON.
Outputs when floor arrives
Outputs when floor arrives
Outputs when floor arrives
Outputs when floor arrives
Outputs when floor arrives
Outputs when floor arrives
Provides audible announcement of an elevator's arrival
on floor
Voice announces the elevator is opening the door
Voice announces the elevator is closing the door
Voice announces the elevator is running upward
Voice announces the elevator is running downward
Voice announces the elevator is overloading
Voice announces the elevator is in emergency medical
12-06-9