Chapter 12 Descriptions of Parameter Settings

02 System Configuration

Car Call Test
Settings 0–164
 Uses the digital keypad as the car command board to call the car
Upward Hall Call Test
Settings 0–164
 Uses the digital keypad as the hall call display board to call the car upward.
Downward Hall Call Test
Settings 0–164
 Uses the digital keypad as the hall call display board to call the car downward.
Auto-test Method
Settings 0–3
 0: test one time when the car runs to the top floor or one time to the bottom floor
 2: If the car does not stop at the bottom floor, the car runs downward and stops at each floor until
arriving the bottom floor, which is regarded as test for one time. If the car stops at the bottom floor,
the car runs upward and stops at each floor until arriving the top floor, which is also regarded as
test for one time.
Number of Times for Auto-test
Settings 0–65535
 Whenever the elevator is activated, the number of times for auto-test counts as one time. When
the number of times for auto-test is 0, the test is finished.
Interval for Auto-test
Settings 0–3600
 The interval starts to count when the elevator stops. Once the interval counts to this parameter
setting value, the elevator automatically executes the auto-test.
Forced Door Opening/Closing Test
Settings
0: No test
1: Test for the top and bottom floor
2: Test for each floor
3: Random call
65535: Continues to random test
0–4
0: Normal mode
12-02-1
Chapter 12 Descriptions of Parameter Settings | IED-S
: You can set this parameter during operation.
Default: 1
Default: 1
Default: 1
Default: 0
Default: 0
Default: 30
Default: 0