Pr.
Parameter Name
First One Forced
13-62
Deceleration Limit
Seconds One Forced
13-63
Deceleration Limit
Third One Forced
13-64
Deceleration Limit
Fourth One Forced
13-65
Deceleration Limit
13-66
Cooling Fan Control
13-99
Drive All Write
Chapter 11 Summary of Parameter Settings | IED-S
Setting Range
Bit 5=1: Enables forced deceleration switch speed
limit (Pr.13-62–Pr.13-65) protection function
0.00–99.99 m/s
0.00–99.99 m/s
0.00–99.99 m/s
0.00–99.99 m/s
0: Cooling fan is always ON.
1: One minute after AC motor drive stops, cooling fan
is OFF.
2: AC motor drive runs and cooling fan is ON; AC
motor drive stops and cooling fan is OFF.
3: Cooling fan is ON to run when preliminary IGBT
temperature (°C) reached.
4: Cooling fan is always OFF.
0–1
11-47
Default
1.00
2.00
3.00
4.00
2
0