Delta IED-S Series User Manual page 399

Integrated elevator drive
Table of Contents

Advertisement

Chapter 14 Fault Codes | IED-S
Code#
KPC-CC01 Display
F185
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F186
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F187
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F188
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F189
Action
Related Parameters
Reset Method
Fault Name
Fault occurs when all IED-S low-voltage and
All inputs are OFF
high-voltage inputs are detected as OFF
Action and Reset
Stops urgently
N/A
Resets automatically after five seconds
Fault Name
Fault occurs when the difference between the position
Upward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 4
value after the fourth one upward forced deceleration
switch activates during upward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
Fault Name
Fault occurs when the difference between the position
Downward forced
and hoistway auto-tuning is larger than Pr.03-16 setting
deceleration 4
value after the fourth one downward forced deceleration
switch activates during downward running
Action and Reset
Stops urgently
Pr.03-16 (Position Difference Protection)
Resets automatically after five seconds
Fault Name
Starting signal
Fault occurs when starting signal is OFF within two
abnormally disappears
seconds as elevator runs direct docking
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
Fault Name
Fault occurs when target floor is lower than current floor
Upward target error in
after giving an upward command as elevator runs direct
direct docking
docking
Action and Reset
Stops urgently
N/A
Resets automatically after 60 seconds
14-18
Description
Description
Description
Description
Description

Advertisement

Table of Contents
loading