Extended Door Close Pre-warning Enabled
Settings
 When the door open extended button lights on, the buzzer on the command board and the
multi-function output terminal setting 155 CLBZ (Door closing pre-warning buzzer) output for the
time set in Pr.05-17 before the door closes.
Door Close Pre-warning Time
Settings
 0–99.9: The voice announces "the elevator is closing" in advance for the time set in Pr.05-18
before the door closes. In the meanwhile, the buzzer on the command board and the
multi-function output terminal setting 155 CLBZ (Door closing pre-warning buzzer) output.
 100.0–199.9: The voice announces "the elevator is closing" in advance for the time set in
Pr.05-18 minus (-) 100.0 seconds before the door closes. At this time, the buzzer on the
command board and the multi-function output terminal setting 155 CLBZ (Door closing
pre-warning buzzer) do not output.
Door Close for Elevator Lock Main Landing
Settings
Door Close Recall at Fire Emergency
Settings
Time for Door Re-open While Closing
Settings
 When the elevator door re-opens before closing, the door reaches its open position first, and then
starts to close until Pr.05-21 setting time arrives.
Automatic Door Open at Fire Emergency
Settings
1–100: If the number of times for door close protection exceeds Pr.05-16 in
one hour, the door remains open and will be no longer automatically close,
and the door close button flashes quickly. In this case, press the door close
button to automatically reset the fault.
0.0–100.0 sec.
0.0–199.9 sec.
0–1
0: Door remains open when the elevator returns to the elevator lock main
landing
1: Door opens for 20 seconds and then closes automatically when the
elevator returns to the elevator lock main landing
0–1
0: Door remains open when the elevator returns to the main landing at fire
emergency
1: Door opens for 20 seconds and then closes automatically when the
elevator returns to the main landing at fire emergency
0.0–6553.5 sec.
0–1
0: Door does not open automatically when the elevator arrives at the
designated floor until you press the door open button continuously. The
elevator door closes automatically once you release the door open button
before the door is in its full open position.
1: Door opens automatically when the elevator arrives at the designated floor
12-05-3
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 5.0
Default: 2.0
Default: 0
Default: 0
Default: 5.0
Default: 0