Chapter 12 Descriptions of Parameter Settings | IED-S
Main Landing for Standby While Idling
Settings 1–64S
 Sets the physical floor for standby when the elevator is idle and exceeds Pr.03-06 setting time.
The elevator automatically runs to the physical floor for standby.
Idle Time Before Returning to the Main Landing for Standby
Settings
 When this parameter is not set to 0, the elevator's returning to the main landing for standby while
idling is enabled. When the elevator does not receive any call within Pr.03-06 setting time, it
automatically runs to the main landing that is set in Pr.03-05.
Car Lighting Disabled While Idling
Settings
 Sets the time the lighting automatically turns off when the elevator does not run for a specified
period. If you set this parameter to 0, this function is disabled.
Car Fan Disabled While Idling
Settings
 Sets the time the fan automatically turns off when the elevator does not run for a specified period.
If you set this parameter to 0, this function is disabled.
UPS Designated Floor
Settings
 When the mains electricity is powered off, and UPS (MI=67) or EPS (MI=54) is activated, the
elevator automatically runs to the physical floor that is set in Pr.03-09 or lands safely to make the
elevator run to the leveling position to automatically open the door and release the passengers.
 1–64: The designated physical floor is 1F to 64F for the front door.
 101–164: The designated physical floor is 1F to 64F for the rear door.
 0: When in UPS mode, you must work with the IED-S multi-function input terminal BALWG
(Balanced switch) (MI=125) to safely land at the nearest floor. If the car weight is heavier than the
counterweight, the car runs downward slowly for safety landing; on the contrary, if the car weight
is lighter than the counterweight, the car runs upward slowly for safety landing.
Light Sensor and Safety Edges Alarm
Settings
 When the light sensor or safety edge activates and exceeds Pr.03-10 setting time, the alarm
raises and the door is forced to close slowly.
 1–99: The alarm raises and the door is not forced to close when the setting time arrives.
 101–199: The alarm raises and the door is forced to close slowly when the setting time minus 100
arrives.
 0 or 100: No alarm and no forced door closing.
 Related parameters: Multi-function output FCL1 (Front door forced closed at low speed)
(MO=112), multi-function output FCL2 (Rear door forced close at low speed) (MO=113)
Service Floor 16–1
Service Floor 32–17
Service Floor 48–33
Service Floor 49–64
0–65535 sec.
0–65535 sec.
0–65535 sec.
1–164
0–199 sec.
12-03-2
Default: 1
Default: 0
Default: 600
Default: 30
Default: 0
Default: 0