 Fault code F141 may occur in the process of hoistway tuning. If this happens, increase the setting
time for Pr.03-24. After the hoistway tuning is finished, change Pr.03-24 to normal setting values.
Specified Floor Protection Time
Settings
 When the elevator runs at high speed, and does not pass through or arrives at the specified floor
within Pr.03-25 setting time, the fault code F143 occurs and an emergency stop is triggered. In
this case, switch to the manual mode first, or press the RESET key on the digital keypad, or press
the external reset device, or power-on again to finish the reset.
Selective Control Mode
Settings
 0: Disabled.
 1: The elevator responds to all hall call signals.
 2: The elevator responds to upward calls from hall call only, not downward calls from hall call.
 3: The elevator responds to downward calls from hall call only, not upward calls from hall call.
Registration Cancel Function
Settings
 1: If passengers press the wrong button in the car command board, press the same button twice
incessantly to cancel the registration.
Security Floor Main Landing
Settings
Security Floor Begin Time
Settings
Security Floor End Time
Settings
 0000–2359: 00:00 to 23:59 in 24-hour clock.
 Within each day setting time, any upward or downward car call makes the elevator automatically
run and stop at security floor and door opens. When you set Pr.03-30 (Security Floor Begin Time)
and Pr.03-31 (Security Floor End Time) to the same value and not 0, the security floor operation
function remains until you set both of them to 0. Security floor operation starts from Pr.03-30 and
ends at Pr.03-31 on the day or until next day. When elevator passes through and stops at security
floor, the door automatically closes or you can press the close button to close the door only when
Pr.05-13 (Disability Door Open Time) setting time ends.
1–45 sec.
0–3
0: Disabled
1: Respond to all hall calls
2: Respond to upward hall calls
3: Respond to downward hall calls
0–1
0: No registration cancel function
1: Registration cancel for car calls
0–164S
0–2359
0–2359
12-03-5
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 20
Default: 0
Default: 1
Default: 0
Default: 0
Default: 0