Chapter 8 Specifications | IED-S
8-1 230V Series
Frame Size
Model IED-_ _ _S21/23A
Applicable Motor Output (kW)
Applicable Motor Output (HP)
Rated Output Capacity (kVA)
Rated Output Current (A)
Maximum Output Voltage (V)
Output Frequency Range (Hz)
Carrier Frequency Range (kHz)
Rated Output Maximum Carrier
Frequency (kHz)
Input Current (A)
Rated Voltage (V)
Rated Frequency (Hz)
Allowed Voltage Tolerance (V)
Allowed Frequency Tolerance (Hz)
Cooling Method
Weight (kg)
NOTE: For single-phase models, see Appendix A Single-phase Applications.
8-2 460V Series
Frame Size
Model IED-_ _ _S43A
Applicable Motor Output (kW)
Applicable Motor Output (HP)
Rated Output Capacity (kVA)
Rated Output Current (A)
Maximum Output Voltage (V)
Output Frequency Range (Hz)
Carrier Frequency Range (kHz)
Rated Output Maximum Carrier
Frequency (kHz)
Input Current (A)
Rated Voltage (V)
Rated Frequency (Hz)
Allowed Voltage Tolerance (V)
Allowed Frequency Tolerance
(Hz)
Cooling Method
Weight (kg)
NOTE:
Input/output current rating in the table above varies with the actual input reactor, transformer, wiring connections and
power supply impedance.
C
055
075
5.5
7.5
7.5
10
9.5
12.5
24
30
10
23
30
8
10
C
055
075
110
150
5.5
7.5
11
15
7.5
10
15
20
10.4 13.5 18.3
24
13
17
23
30
2–15
10
14
17
24
30
8
10
10
10
8-2
110
150
11
15
15
20
19
25
45
58
Proportional to input voltage
0.00–400.00
2–15
47
56
200–240 / Three-phase
50/60
±10% (180–264)
±5% (47–63)
Fan cooling
10
13
D
185
220
300
18.5
22
30
25
30
40
30.3
36
46.2
38
45
58
Proportional to input voltage
0.00–400.00
8
37
47
58
380–480 / Three-phase
50 / 60
±10% (342–528)
±5% (47–63)
Fan cooling
10
13
14.5
D
185
220
18.5
22
25
30
29
34
77
87
8
73
90
13
13
E
370
450
550
750
37
45
55
75
50
60
75
100
63.7
80
96.4 116.3
80
100
128
165
2–9
2–6
6
80
100
128
165
36
36
50
50

Advertisement