Delta IED-S Series User Manual page 193

Integrated elevator drive
Table of Contents

Advertisement

Chapter 10 Auto-tuning Process | IED-S
 If the actual floor is from B1F to 10F, then the lowest physical floor is 1; the highest physical
floor is 11.
 When using group controls, set the physical floor based on the highest and lowest physical
floors.
Example:
If the actual floor for Elevator 1 is B1F–9F,
If the actual floor for Elevator 2 is 1F–10F,
Single
Control
Group
Control
Pr.03-00 Hoistway Auto-tuning
 During hoistway auto-tuning, the displayed value for Pr.03-00 is 0. It automatically clears to
0 until the auto-tuning process is finished.
 NOTE: If you stop the auto-tuning process by setting Pr.03-00 to 0, the auto-tuning process
stops but the elevator cannot run normally. You must finish the tuning process once it starts.
Pr.03-67 Brake Test Starting
Elevator/Physical Floor
Elevator 1
Elevator 2
Elevator/Physical Floor
Elevator 1
Elevator 2
Press
Press
Press
Press
Lowest Physical Floor
1
1
Lowest Physical Floor
1
2
10-26
Highest Physical Floor
10
10
Highest Physical Floor
10
11