Table of Contents

Advertisement

Third One Forced Deceleration Limit
Settings 0.00–99.99 m/s
 See Pr.13-16 parameter descriptions for details.
Fourth One Forced Deceleration Limit
Settings 0.00–99.99 m/s
 See Pr.13-16 parameter descriptions for details.
Cooling Fan Control
Settings 0: Cooling fan is always ON.
 Use this parameter for fan control.
 When set to 3, the fan starts to run until heat sink temperature is less than 40°C if temperature
exceed 40°C.
Drive All Write
Settings 0–1
 1: Automatically write all parameters related to drive into the drive. The setting value
automatically returns to 0 after you finish the setting.
1: One minute after AC motor drive stops, cooling fan is OFF.
2: AC motor drive runs and cooling fan is ON; AC motor drive stops and
cooling fan is OFF.
3: Cooling fan is ON to run when preliminary IGBT temperature (°C) reached.
4: Cooling fan is always OFF.
12-13-15
Chapter 12 Descriptions of Parameter Settings | IED-S
Default: 3.00
Default: 4.00
Default: 2
Default: 0