Code#
KPC-CC01 Display
F135
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F136
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F137
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F138
Action
Related Parameters
Reset Method
Code#
KPC-CC01 Display
F139
Action
Fault Name
Fault occurs when 150% (Forklift overload switch) is ON
Load exceeds 150%
under non-manual mode
Action and Reset
Stops urgently
MI=111 150% (Forklift overload switch)
Resets automatically when 150% (Forklift overload switch) is OFF for 10
seconds
Fault Name
Fault occurs when FXNO (N.O. contact of MPSCC
FX (MPSCC) feedback
(Motor Phase Short Circuit Contactor)) is not OFF after
ON error
FX (Motor Phase Short Circuit Contactor (PM))
deactivates (OFF)
Action and Reset
Stops urgently
MO=6 FX (Motor Phase Short Circuit Contactor (PM))
MI=63 FXNO (N.O. contact of MPSCC (Motor Phase Short Circuit Contactor))
Press the upward or downward operation button for the manual mode, press the
RESET key on the digital keypad, press the external reset device, or power-on
again (choose either)
Fault Name
Safety hatch high
Fault occurs when there is an error in the safety hatch
voltage error
signal for the elevator system (high voltage)
Action and Reset
Stops urgently
MI=15 SFH (Safety hatch high voltage)
Resets automatically once the signal is normal
Fault Name
Fault occurs when elevator exceeds the leveling sensor
Upward operation at
position while running upward until it stops at certain
stop exceeds
floor
Action and Reset
Acts immediately
N/A
Resets automatically
Fault Name
Fault occurs when elevator exceeds the leveling sensor
Downward operation at
position while running downward until it stops at certain
stop exceeds
floor
Action and Reset
Acts immediately
14-7
Chapter 14 Fault Codes | IED-S
Description
Description
Description
Description
Description

Advertisement