Delta IED-S Series User Manual page 266

Integrated elevator drive
Table of Contents

Advertisement

 If you see code number from 1001 to 1100 display on the keypad, they are the drive's warning
codes. For more information on these warning codes, see Chapter 13 Warning Codes in the
VFD-ED user manual. Ignore the thousands digits when referring to the VFD-ED user manual.
 If you see code number from E001 to E100 display on the keypad, they are the drive's fault codes.
For more information on these fault codes, see Chapter 14 Fault Codes in the VFD-ED user
manual.
194: ULS1 over-speed
195: ULS2 over-speed
196: ULS3 over-speed
197: ULS4 over-speed
198: DLS4 over-speed
199: DLS3 over-speed
200: DLS2 over-speed
201: DLS1 over-speed
202: Target error 1
203: Target error 2
204: Target error 3
205: Target error 4
221: GSH (Gate safety hatch high voltage) is OFF
222: GSH (Gate safety hatch high voltage) contact sticking
223: DSH (Layer door safety hatch high voltage) is OFF
224: DSH (Layer door safety hatch high voltage) contact sticking
225: Front door open time exceeds
226: Front door close time exceeds
227: Rear door open time exceeds
228: Rear door close time exceeds
229: Front door close times exceed
230: Rear door close times exceed
231: GSL (Gate safety hatch low voltage) is OFF
232: GSL (Gate safety hatch low voltage) contact sticking
233: DSL (Layer door safety hatch low voltage) is OFF
234: DSL (Layer door safety hatch low voltage) contact sticking
235: Discharge resistance temperature is too high
236: Watchdog action
1109: Braking force, Under test
1110: Inspection, Unqualified, Braking force
1111: Leveling, Unqualified, Braking force
1112: Braking force, Test, Qualified
1113: Fault, Unqualified, Braking force
1114: Button, Unqualified, Braking force
1115: Wait, Braking force test
1116: Recall, Braking force test
1117: Inspection, Unqualified, Door unlock board
1118: Doorlock, Unqualified, Door unlock board
1119: Door unlock board, Test, Overtime
1120: Door unlock board, Under test
1127: Highest floor warning
1128: Elevator lock main landing warning
1129: Elevator main landing warning
1130: Main landing at fire emergency warning
1132: Fireman class II invalid
1133: Motor temperature at front door overheats
1134: Motor temperature at rear door overheats
1135: CAR+/CAR- time-out
1136: Running time-out during auto-tuning
1137: Auto-tuning time-out
1138: Coin cell battery is at low voltage
12-01-3
Chapter 12 Descriptions of Parameter Settings | IED-S

Advertisement

Table of Contents
loading

Table of Contents