Chapter 12 Descriptions of Parameter Settings | IED-S
0000–2359: 00:00 to 23:59 in 24-hour clock.
Sets the beginning time for the second downward peak hours. See Pr.03-90 peak running in
group control operation for details.
Downward Peak 2 End
Settings
0000–2359: 00:00 to 23:59 in 24-hour clock.
Sets the end time for the second downward peak hours. See Pr.03-90 peak running in group
control operation for details.
Number of Full-load at Upward Peak
Number of Full-load at Downward Peak
Settings
See Pr.03-90 peak running in group control operation for details.
Number of Calls for Downward Peak
Settings
See Pr.03-90 peak running in group control operation for details.
Holding Time for Upward and Downward Peak
Settings
See Pr.03-90 peak running in group control operation for details.
Holding Time at Random Floor
Settings
See Pr.03-90 peak running in group control operation for details.
Number of Full-load at Random Floor
Settings
See Pr.03-90 peak running in group control operation for details.
Automatically Runs Downward at Downward Peak
Settings
Upward peak running:
1. Goal: To prevent too many passengers from waiting the elevator in the lobby during peak
hours such as on-duty hour
2. Method: After elevator finishes responding to car calls and hall calls during upward peak
running, it automatically runs to Pr.03-68 (First Main Group Control) and door opens for one
time. When elevator runs upward and passes through Pr.03-68 (First Main Group Control), it
automatically stops and door opens for one time. Upward peak running and downward peak
running have the same priority and can coexist at the same time. These two modes have
priority over peak running at random floor. If elevator is currently in the mode of peak running
at random floor, it is cancelled once conditions that trigger upward or downward peaking
0–2359
0–65535
0–65535
0–65535 sec.
0–65535 sec.
0–65535
0–1
0: Does not automatically run downward when elevator is automatically
recalled to the position near top floor for standby during downward peak
running
1: Automatically runs downward when elevator is automatically recalled to the
position near top floor for standby during downward peak running
12-03-16
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0