Chapter 10 Auto-tuning Process | IED-S

10-1 Tuning in Easy Steps

1. Motor parameters:
Pr.13-01 Control Mode
Pr.13-03 Elevator Rated Frequency
Pr.13-04 Motor Rated Frequency
Pr.13-05 Motor Rated Voltage
Pr.13-06 Motor Rated Current
Pr.13-07 Motor Rated Power
Pr.13-08 Motor Rated Speed
Pr.13-09 Number of Motor Poles
Pr.13-22 Selection of Encoder
Pr.13-23 Encoder Pulse
Pr.13-24 Encoder Input Type Setting
2. Input / Output Parameters:
Pr.06-xx Contacts of Main Control Board
Pr.07-xx Contacts of Cartop Board
3. Motor Parameter Auto-tuning
Pr.13-21 Motor Auto-tuning (IM, PM)
Pr.13-21 Auto-measures the magnetic pole angle (PM)
4. Mechanical Inertia:
Pr.13-26 Suspension Ratio
Pr.13-27 Gear Ratio
Pr.13-28 Main Sheave Diameter
Pr.13-29 Elevator Rated Speed
Pr.13-60 Maximum Current during Acceleration
Pr.13-30 Mechanical Inertia Ratio
5. Tuning in Manual Mode:
Pr.02-06 Forced Door Opening/Closing Test
Pr.03-51 ICB (Car Command Board) Function Setting
6. Tuning in Automatic Mode:
Pr.03-01 Highest Physical Floor
Pr.03-02 Lowest Physical Floor
Pr.04-03 Hoistway Auto-tuning Speed
Pr.03-24 Constant Running Protection Time
Pr.03-00 Hoistway Auto-tuning
Pr.03-60–Pr.03-67 Manual Braking Force Test
7. Group Control:
Pr.03-03 Group Control Station Number
Pr.03-04 Group Control Enabled