Delta IED-S Series User Manual page 56

Integrated elevator drive
Table of Contents

Advertisement

Code
N. C. (Normally Closed) contact of layer door safety (DS) hatch
35
DSNC
contactor
36
TCIN
Traveling cable insertion
37
SWNC
N.C. contact of operation contactor (SW)
38
BY1NC
N.C. contact of Brake-1 contactor (BY1)
39
BY2NC
N.C. contact of Brake-2 contactor (BY2)
40
BY3NC
N.C. contact of Brake-3 contactor (BY3)
41
BK1
Brake-1 travel switch
42
BK2
Brake-2 travel switch
43
BK3
Brake-3 travel switch
44
LSU
Upper limit switch
45
LSD
Lower limit switch
46
ULS1
First one upward forced deceleration
47
ULS2
Second one upward forced deceleration
48
ULS3
Third one upward forced deceleration
49
DLS1
First one downward forced deceleration
50
DLS2
Second one downward forced deceleration
51
DLS3
Third one downward forced deceleration
52
IUS
Inspection uppermost limit switch
53
IDS
Inspection lowermost limit switch
54
PARK
Elevator lock
55
FIRM
Main landing recall at fire emergency
56
FIRS
Secondary landing recall at fire emergency
57
FIRS1
Fireman class I
58
FIRS2
Fireman class II
59
FLOOD
Not auto-reset at flood
60
FLOODA
Auto-reset at flood
61
MTS
Motor temperature overheat
62
ERP
Seismic P-wave (minor earthquake)
63
ERS
Seismic S-wave (small earthquake)
64
ERH
Severe earthquake
65
EPS
Emergency Power Supply
66
GOV
Governor
67
DBP
Doorlock bypass
68
BUNC
N.C. contact of drive's brake unit (BU) contactor
69
IBRTS
Drive's discharge resistance temperature switch
70
UPK
Upward peak running
71
DPK
Downward peak running
72
SX1
Door zone signal
Description
3-31
Chapter 3 Wiring | IED-S

Advertisement

Table of Contents
loading

Table of Contents