Setting the force
Set the cutting force that is used in each of the condition numbers.
Setting range : 1 to 38
Operation
1
Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
2
Press the [4] key (FORCE).
FORCE setting screen is displayed.
* Display may vary depending on the selected condition number.
3
Press the POSITION (
number (CONDITION No.).
4
Press the POSITION (
setting value.
5
Confirm the setting and press the [ENTER] key (SET).
Setting will be confirmed and it will return to CONDITION setting screen
(1/3).
6
Press the [COND/TEST] key.
It will return to default screen.
) keys and select the condition
) keys and increase or decrease the
2-50
Supplement
Perform the settings in Normal mode.
Supplement
It will return to CONDITION setting screen (1/3)
without changing the settings when you press
the [ESC] key (CANCEL).
Supplement
You can set the range between 1 and 38.
Need help?
Do you have a question about the CE7000 Series and is the answer not in the manual?
Questions and answers