6.9
Adjustment of the Scanner Section
6.9.1
Adjustment carriages-1 and -2 positions
<Procedure>
(1)
Take off the RADF.
(2)
Take off the original glass.
(3)
Take off the top right cover.
(4)
Take off the top rear cover.
(5)
Move the carriage-2 toward the exit side.
Note:
Rotate the drive pulley to move the carriage.
(6)
Loosen the screws fixing the front side pulley
bracket, make the sections A and B of the
carriage-2 touch with the inside of the exit
side frame and screw them up.
Note:
Make sure that the sections A and B of the
carriage-2 touch with the exit side frame.
(7)
Put carriage-1 on the rail. Then make
sections C and D of carriage-1 touch the
inside of the exit side frame and tighten the
front and rear sides of the bracket with the
screws.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Carriage-2
[ Rear ]
Exit side frame
B
Fig. 6-28
Bracket
Carriage-1
D
[ Rear ]
Enlarged view of carriage
Fig. 6-29
e-STUDIO556/656/756/856/557/657/757/857
6 - 49
Pulley bracket
[Front]
A
Enlarged view of carriage
Bracket
Exit frame
C
[ Front ]