6.6.8
RGB conversion method selection
The color space conversion method of image is decided at color-scanning.
Original mode
Text/
Text
Photo
Photo
8319
8320
8321
<Procedure>
Procedure is same as that of  P.6-34 "6.6.2 Density adjustment".
6.6.9
Adjustment of saturation
The saturation of the scanned image is adjusted for color-scanning.
Original mode
Text/
Text
Photo
Photo
8324
8325
8326
<Procedure>
Procedure is same as that of  P.6-34 "6.6.2 Density adjustment".
e-STUDIO556/656/756/856/557/657/757/857
ADJUSTMENT
Item to be
User
adjusted
Custom
8372
RGB conversion
method selection
Item to be
User
adjusted
Custom
8373
Adjustment of
saturation
6 - 38
< Adjustment Mode (05) >
Remarks
0: sRGB
1: AppleRGB
2: ROMMRGB
3: AdobeRGB
(Default: 0).
< Adjustment Mode (05) >
Remarks
The larger the value is, the brighter the image
becomes.
The smaller the value is, the duller the image
becomes.
Acceptable values: 0 to 255 (Default: 128)