Advertisement

Notes:
1. When replacing the recovery blade, be
sure to separate it completely because it
is attached with the two-sided adhesive
tape.
2. Attach the recovery blade by pushing its
lower edge against the step of the cleaner
frame. (A in the figure on the right)
4.8.5
Cleaning brush
(1)
Take off the drum.
( P.4-75 "4.8.2 Drum thermistor (THM5)
and Drum")
(2)
Pull out the shaft held on the rear side to take
out the cleaning brush.
4.8.6
Image quality sensor (S14)
(1)
Take off the cleaner unit.
( P.4-75 "4.8.1 Cleaner unit")
(2)
Disconnect 1 connector and remove 2
screws to take off the image quality sensor.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
Recovery blade
Cleaner flame
Fig. 4-216
Cleaning brush
Fig. 4-217
Image quality sensor
Fig. 4-218