[E090] Image data delay jam
Classification
Other paper jam
Check item
Other
Power
SYS board
SLG board
(e-STUDIO556/656/756/856)
HDD
Replace parts
Page memory
HDD
SYS board
SLG board
[E091]Other time-out jam
Classification
Other paper jam
Check item
Other
Power
SYS board
LGC board
PLG board
HDD
Replace parts
Page memory
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Image data to be printed cannot be prepared.
Remove the paper remained in front of the registration sensor.
If the error still occurs, check the following.
Check if the error is cleared by turning the power OFF and then back
ON.
Connector check
Page memory check
Board check.
Connector check
Harness check.
Board check.
Harness check.
(e-STUDIO556/656/756/856)
The equipment does not operate normally because abnormality occurred
on an interface between the SYS board and engine firmware.
Remove the paper remained in front of the registration sensor.
If the error still occurs, check the following.
Check if the error is cleared by turning the power OFF and then back
ON.
Connector check
Page memory check
Board check.
Connector check
Harness check.
Board check.
Connector check
Harness check.
Board check.
Harness check.
8 - 43