[C] Image position adjustment of the primary scanning direction
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON.  (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
Press [FAX] [START] to make a copy at the mode of A3 (LD), 100% and the 2nd drawer.
(4)
Measure the distance B from the left edge of the paper to 100 mm of the copied image of the
ruler.
(5)
Check if the distance B is within the range of 100±1.0 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)  (Key in the code [3030])  [START]
 (Key in a value (acceptable values: 63 to 193))
 Press the [OK] or the [INTERRUPT] button (stored in memory).
 ("100% A" is displayed.)
* The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower (approx. 0.04 mm/step).
e-STUDIO556/656/756/856/557/657/757/857
ADJUSTMENT
Copied image of the ruler
Fig. 6-18
6 - 18
Feeding direction