[B] Installation of lens unit
(1)
Attach the lens unit and fix it temporarily with
2 screws.
(2)
Match the center scale of the plate in which
the unit is to be installed and the rightmost
scale of the adjusting hole on the lens unit
plate.
(3)
Tighten 4 screws securely to fix the lens unit
while pushing it to the rear side.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
Screw
[ Rear ]
Screw
Screw
[ Front ]