4.13.44 Original width detection sensor-1 (SR6)
(1)
Take off the feeder lower guide unit.
( P.4-172 "4.13.41 Feeder lower guide
unit")
(2)
Disconnect 1 connector. Lift the actuator,
release 2 latches and take off the original
width detection sensor-1.
4.13.45 Original registration sensor (SR5)
(1)
Take off the feeder lower guide unit.
( P.4-172 "4.13.41 Feeder lower guide
unit")
(2)
Disconnect 1 connector. Release 2 latches
and take off the original registration sensor.
4.13.46 Original exit sensor (SR12)
(1)
Take off the assembly of the exit guide and
the exit/reverse guide.
( P.4-142 "4.13.11 Exit guide / Exit/reverse
guide / Reading end guide")
(2)
Remove 2 screws and take off the 2 leaf
springs.