(4)
Take off the tray-up motor.
Note:
Align the boss of the gear and the hole of the
cover when installing the tray-up motor.
4.6.6
Feed driving unit
(1)
Take off the switching regulator.
( P.9-9 "9.1.11 Switching regulator (PS) (e-
STUDIO556/656/756/856)")
( P.9-9 "9.1.12 Switching regulator (PS)
(e-STUDIO557/657/757/857)")
(2)
Take off the feed motor.
( P.4-58 "4.6.4 Feed motor (M20)")
(3)
Disconnect 1 connector and remove 5
screws to take off the AC input.
(4)
Release the harness from the clamp and
remove 6 screws to take off the feed driving
unit.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Tray-up motor
Boss
Fig. 4-163
AC inlet
Screw
Screw
Fig. 4-164
Feed drive unit
Screw
Screw
Fig. 4-165
e-STUDIO556/656/756/856/557/657/757/857
4 - 59
Boss
Screw
Connector
Screw