Download Print this page

Toshiba e-STUDIO556 Service Manual page 244

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

(5)
Take off the shaft of the separation finger by
sliding it to the front side.
(6)
Remove 1 screw each to pull out the
separation finger [1] from the shaft.
(7)
Remove 1 E-ring and 1 screw, and then take
off the separation finger [2] (in the middle)
from the shaft.
Notes:
1. When assembling, be sure that the arm
[1] is in the hole [2] of the separation
finger.
2. Make sure you assemble the drum
separation finger with the weight screws
[1] and stopper [3] in the correct direction.
3. Be sure to install the separation finger in
the correct position because the shape of
the separation finger in the middle and on
the outer side is different.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
[1]
Fig. 4-222
A
[2]
[1]
Fig. 4-223
[3]
[1]
Fig. 4-224
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 80
( 1 )
( 2 )
[2]
B
[1]
[3]
[2]
[1]

Advertisement